Products

Our products

Quality can be relied upon

LZM-HDP01 Water-based Epoxy Self-drying Paint (Two Components)

1. Product Overview:

  • ◆Category: This product is a two-component self-drying paint that uses high-grade resin and curing agent as film-forming substances;
  • ◆Composition: High-grade resins, pigments, fillers, additives, water, etc;
  • ◆Features: :
    1. This product uses water as the dispersion medium, has no ignition point at room temperature, and is non-combustible and non-explosive.
    2. Excellent adhesion, scrub and chemical resistance;
    3. There are no toxic and harmful substances in the construction process and the coating film-forming process, which is in line with environmental protection requirements.

2. Scope of application: It is suitable for heavy anti-corrosion fields (such as containers, ships, offshore platforms, docks and other marine facilities, petrochemical plant pipelines and storage tanks, as well as anti-rust and anti-corrosion of steel components in metallurgy, electric power, food, textile and other industries)

3. Technical indicators

project index
Color and appearance (Part A) viscous liquids of various colors / (Part B) transparent liquids or milky liquids
Viscosity (coat-4 cups, 23±2°C) (Part A) ≥60 seconds
Solids content (120°C/2 hours) ≥ 45% (component A + component B.)
Adhesion (circle method) ≤ level 1
Impact strength ≥50 kg.cm
Pencil hardness ≥2H
Flexibility ≤1 mm
Salt water resistance (3% NaCl solution) 500 hours does not blister, does not fall off, allows for slight discoloration
Salt spray resistance (neutral salt spray) 1000 hours non-foaming, does not fall off, allows slight discoloration
Drying and curing (23±2°C, relative humidity ≤80%) Surface dry ≤ 1 hour/dry ≤ 24 hours/hard dry ≤ 7 days

4, the construction reference:

  • ◆Surface treatment: Safely remove impurities such as floating ash, floating rust, oil stain on the surface of the workpiece to be painted, so that the surface of the workpiece to be painted is clean and dry;
  • ◆Construction method: use airless or air spraying, spraying should use a large-caliber spray gun;
  • ◆Mixing ratio: Component A: Component B = 4:1 (weight ratio, the proportion is slightly different due to different colors), please stir the A and B components well before mixing;
  • ◆Dilution ratio: (A component + B component): water = 1:0.05~0.15, let stand for 5~10 minutes and then filter and spray with a 120 mesh filter cloth;
  • ◆Application Viscosity: Spraying: 20-25 seconds (coating - 4 cups/23±2°C);
  • ◆Recoat interval: not less than 12 hours (23±2°C);
  • ◆Tank life: 1~2 hours (23±2°C, the validity period shortens with the increase of temperature); (Note: The life in the tank refers to the service life after the mixing of components A and B)
  • ◆Drying method: self-drying at room temperature (15°C~40°C is appropriate), or 80°C~90°C drying (20~25 minutes);
  • ◆Theoretical coating rate: 8~9 square meters/kg (calculated as 20 microns of dry film), the actual amount depends on the substrate structure and construction method。

5. Precautions:

  • ◆The quality of the metal substrate treatment will directly affect the final effect and protective performance of the coating film;
  • ◆The substrate must be coated as soon as possible after treatment, and the coating interval should not be less than 12 hours and not more than 7 days (at 25°C);
  • ◆The construction temperature is required to be between 15 °C and 40 °C, and above the dew point by more than 3 °C, and the relative humidity is ≥ 80%.;
  • ◆Outdoor construction is not allowed on rainy days, and if it has been constructed, it is necessary to cover it with a tarpaulin to protect the paint film that is not completely dry;
  • ◆This product should be stored in a cool and ventilated place at a temperature of 5 °C ~ 45 °C, and the validity period is one year。

6. Storage and packaging:

  • ◆Packing: 16kg/drum for component A, 4kg/drum for component B, and the specific packaging specifications can also be adjusted according to the actual situation;
  • ◆Transportation: Transported as non-dangerous goods。

LZD-HTH01 Water-based Epoxy Red Anticorrosive Primer (Two Components)

1. Product Overview:

  • ◆Category: This product is a two-component self-drying paint that uses high-grade resin and curing agent as film-forming substances;
  • ◆Composition: High-grade resins, pigments, fillers, additives, water, etc;
  • ◆Features: :
    1. This product uses water as the dispersion medium, has no ignition point at room temperature, and is non-combustible and non-explosive.
    2. Excellent matching and interlayer adhesion with most water-based and oil-based topcoats
    3. Excellent adhesion, scrub and chemical resistance;
    4. There are no toxic and harmful substances in the construction process and the coating film forming process, which is in line with environmental protection requirements and EU RoHs directives.

2. Scope of application: Suitable for medium corrosion protection (e.g. steel structures, containers, etc.)

3. Technical indicators(Typical Data)

project index
Color and appearance (Part A) iron red viscous liquid / (Part B) milky white liquid
Fineness ≤40μm
Viscosity (coat-4 cups, 23±2°C) (Part A) ≥40 seconds
Solids content (120°C/2 hours) ≥ 50% (component A + component B.)
Adhesion (circle method) ≤ level 1
Impact strength ≥50 kg.cm
Pencil hardness ≥2H
Flexibility ≤1 mm
Salt water resistance (3% NaCl solution, 2 passes of 50~60um thickness) 300 hours does not blister, does not fall off, allows for slight discoloration
Salt spray resistance (neutral salt spray, double film thickness 50~60um) 168 hours non-foaming, does not fall off, allows slight discoloration
Drying and curing (23±2°C, relative humidity ≤80%) Surface dry ≤ 1 hour/dry ≤ 24 hours/hard dry ≤ 7 days

4, the construction reference:

  • ◆Surface treatment: Safely remove impurities such as floating ash, floating rust, oil stain on the surface of the workpiece to be painted, so that the surface of the workpiece to be painted is clean and dry;
  • ◆Construction method: Spray or brush can be applied;
  • ◆Mixing ratio: Component A: Component B = 4:1 (weight ratio), please stir the A and B components well before mixing;
  • ◆Dilution ratio: (Component A + Component B): water = 1:0.15~0.25, let stand for 5~10 minutes and then filter and spray with a 200 mesh filter cloth;
  • ◆Application Viscosity: Spray: 25-30 seconds (apply -4 cups/23±2°C), brush: 30-50 seconds (apply -4 cups/23±2°C);
  • ◆Recoat interval: Minimum: 4 hours (23±2°C) / Max: 48 hours (23±2°C);
  • ◆Tank life: 1~2 hours (23±2°C, the validity period shortens with the increase of temperature); (Note: The life in the tank refers to the service life after the mixing of components A and B)
  • ◆Drying method: self-drying at room temperature (15°C~40°C is appropriate), or 80°C~90°C drying (20~25 minutes);
  • ◆Theoretical coating rate: 6.5 square meters/kg (20 microns of dry film), the actual amount depends on the substrate structure and construction method。

5. Precautions:

  • ◆The quality of the metal substrate treatment will directly affect the final effect and protective performance of the coating film;
  • ◆The substrate must be coated as soon as possible after treatment, and the coating interval should not be less than 12 hours and not more than 7 days (at 25°C);
  • ◆The construction temperature is required to be between 15 °C and 40 °C, and above the dew point by more than 3 °C, and the relative humidity is ≥ 80%.;
  • ◆Outdoor construction is not allowed on rainy days, and if it has been constructed, it is necessary to cover it with a tarpaulin to protect the paint film that is not completely dry;
  • ◆This product should be stored in a cool and ventilated place at a temperature of 5 °C ~ 45 °C, and the validity period is one year。

6. Storage and packaging:

  • ◆Packing: 16kg/drum for component A, 4kg/drum for component B, and the specific packaging specifications can also be adjusted according to the actual situation;
  • ◆Transportation: Transported as non-dangerous goods。

LZD-HLSX water-based zinc epoxy phosphate anticorrosive primer

Product Description

:

This product is a two-component coating, excellent anti-rust performance and oil resistance, water resistance, salt water resistance, solvent resistance, tough and dense paint film and good adhesion to the substrate, convenient construction, no environmental pollution, and epoxy, polyurethane, rubber, vinyl resin and other topcoats have good matching and interlayer adhesion.

Product Use

:

It is suitable for anti-rust, anti-corrosion primer and zinc-free coating primer for steel; It is used for anti-rust and anti-corrosion of steel components in ships, containers, offshore platforms, docks and other marine facilities, petrochemical plant pipelines and storage tanks, metallurgy, electric power, food, textiles and other industries.

Typical data for technology

Color & Appearance Iron red, flat coating natural drying, 25 °C, 75%RH Stem, h 1
density, strength, kg g/cm3 2.8-3.0 Hard work, h 24
Tumble dry at 80 °C 20min
Recommended dry film thickness, um 60-80 impact strength, kg·cm 50
Fineness, um 40 flexibility, mm 1
Viscosity, s, 25 40-60 volumetric solids, % ≥50
Theoretical dosage, g/m2 150-180 (30um dry film). resistant to 3% saline, 500h No blistering, no rust
Adhesion, grade 1 salt spray resistance, 168h, grade 2

Construction guidance and other matters

  1. 1. Carefully clean the surface of the coated object before painting, and spray or projectile rust removal to meet the Sa25 level rust removal standard; The rust removal of manual and power tools has reached the St2 level of rust removal;
  2. 2. Before use, the A component is fully stirred evenly, prepared according to the ratio of A:B=7:1 (weight ratio), stirred evenly and cured for 10min, and filtered with a 120 mesh filter. Airless or air-sprayed; The coating interval shall not be less than 15h and not more than 7d (25°C);
  3. 3. Tank life: 3h (decreases with the increase of temperature);
  4. 4. The construction temperature is required to be above 15 °C, below 40 °C, and 3 °C above the dew point, and the relative humidity shall not exceed 80%;
  5. 5. Thinner: add 5%-10% pure drinking water or clean water according to the construction viscosity requirements;
  6. 6. Packing: A component 21Kg per barrel; Component B: 3 kg per barrel;
  7. 7. Storage period: 6 months from the date of production. [

LZD-HFX01 waterborne epoxy zinc-rich anticorrosive primer (three components).

1. Product Overview:

  • ◆ Category: The product is a three-component self-drying paint with high-grade resin as the film-forming substance;
  • ◆ Composition: high-grade resin, pigment, filler, additives, water, etc.;
  • ◆ Features:
    • This product uses water as the dispersion medium, has no ignition point at room temperature, and is non-combustible and non-explosive;
    • Excellent matching and interlayer adhesion with most water-based and oil-based topcoats;
    • It has excellent adhesion, grinding resistance, rust resistance and chemical resistance;
    • There are no toxic and harmful substances in the construction process and the coating film forming process, which is in line with environmental protection requirements and EU RoHs directives.

2. Scope of application: It is applicable to the field of heavy anti-corrosion (such as containers, ships, offshore platforms, wharves and other marine facilities, petrochemical plant pipelines and storage tanks, as well as anti-rust and anti-corrosion of steel components in metallurgy, electric power, food, textile and other industries).

3. Technical indicators (typical data):

.) .)
Projects Indicators
Color and appearance (Part A) Brownish-yellow viscous liquid / (Part B) grey powder / (Part C) transparent liquid
Viscosity (coated - 4 cups, 23±2 °C) (Component A ≥ 40 seconds
Solids content (120°C/2 hours≥ 60% (part A + part B + part C
Adhesion (circle method). ≤ level 1
Impact strength ≥50 cm.kg
Pencil hardness ≥H
Flexibility ≤1 mm
Salt water resistance (3% NaCl solution 1000 hours non-foaming, does not fall off, allows slight discoloration
Salt spray resistance (neutral salt spray). 1000 hours non-foaming, does not fall off, allows slight discoloration
Drying and curing (23±2°C, relative humidity ≤80%) Surface drying≤ 1 hour/dry ≤ 24 hours/hard drying≤7 days

(Note: The test conditions for salt water and salt spray resistance are: 1. Substrate: cold-rolled steel plate with degreasing and grinding; 2. Coating: spray epoxy zinc-rich primer twice + painted twice in epoxy micaceous iron; 3. Drying: Drying at room temperature for seven days. )

Fourth, the construction reference:

  • ◆Surface treatment: Safely remove impurities such as floating ash, floating rust, oil stain on the surface of the workpiece to be painted, and make the surface of the workpiece to be painted clean and dry;
  • ◆ Construction method: use airless or air spraying, spraying should use a large-caliber spray gun;
  • ◆ Mixing ratio: Component A: Component B: Component C = 4.5:4.5:1 (weight ratio), please stir the A and C components well before mixing;
  • ◆Dilution ratio: (component A + component B + component C): water = 1:0.05~0.25, let stand for 5~10 minutes and then filter and spray with a 120 mesh filter cloth;
  • ◆ Construction viscosity: Spraying: 30-40 seconds (coating -4 cups/23±2 °C),
  • ◆Recoat interval: Minimum: 12 hours (23±2°C) / Max: 7 days (23±2°C);
  • ◆ Tank life: 1~2 hours (23±2°C, the validity period shortens with the increase of temperature); (Note: The life in the tank refers to the service life of A and B components after mixing).
  • ◆Drying method: self-drying at room temperature (15°C~40°C is appropriate), or 80°C~90°C drying (20~25 minutes);
  • ◆ Theoretical coating rate: 4 square meters/kg (based on 30 microns of dry film), the actual amount depends on the substrate structure and construction method

5. Precautions:

  • ◆The quality of metal substrate treatment will directly affect the final effect and protective performance of the coating film;
  • ◆ The substrate must be coated as soon as possible after treatment, and the coating interval is not less than 12 hours and not more than 7 days (under the condition of 25 °C);
  • ◆ Outdoor construction can not be done on rainy days, if it has been constructed, it is necessary to cover it with a tarpaulin to protect the paint film that is not completely dry;
  • ◆ The construction temperature is required to be above 15 °C and below 40 °C, and above the dew point by more than 3 °C, and the relative humidity is ≥ 80%;
  • ◆ This product should be stored in a cool and ventilated place, the temperature is 5 °C ~ 45 °C, the validity period is one year, if the storage period is exceeded, it can still be used after passing the inspection.

6. Packing and Shipping:

  • ◆ Packing: component A 9kg/barrel, component B 9kg/barrel, component C 2kg/barrel, specific packaging specifications can also be adjusted according to the actual situation;
  • ◆ Transportation: Transported as non-dangerous goods.

LZD-HYT01 water-based epoxy micaceous iron anticorrosive paint (two components).

1. Product Overview:

  • ◆Category: The product is a two-component self-drying paint with high-grade resin as the film-forming substance;
  • ◆ Composition: high-grade resin, pigment, filler, additives, water, etc.;
  • ◆ Features:
    • This product uses water as the dispersion medium, has no ignition point at room temperature, and is non-combustible and non-explosive;
    • Excellent matching and interlayer adhesion with most water-based and oil-based topcoats;
    • It has excellent adhesion, grinding resistance, rust resistance and chemical resistance;
    • There are no toxic and harmful substances in the construction process and the coating film forming process, which is in line with environmental protection requirements and EU RoHs directives.

2. Scope of application: suitable for heavy anti-corrosion field (can be used as an intermediate coating for high-performance anti-rust paint such as epoxy zinc-rich primer to enhance the protection of the coating.) performance, it can also be used as a sealing coating on the surface of zinc spraying or galvanizing layers for metals such as steel).

3. Technical indicators (typical data):

Projects Indicators
Color and appearance (Part A) Iron Black Viscous Liquid / (Part B) Clear Liquid
Viscosity (coated - 4 cups, 23±2 °C) (component A). ≥ 80 seconds
Solids content (120°C/2 hours). ≥ 60% (part A + part B).
Adhesion (circle method). ≤ level 1
Impact strength ≥50 cm.kg
Pencil hardness ≥H
Flexibility ≤1 mm
Salt water resistance (3% NaCl solution). 500 hours does not blister, does not fall off, allows for slight discoloration
Salt spray resistance (neutral salt spray). 1000 hours non-foaming, does not fall off, allows slight discoloration
Drying and curing (23±2°C, relative humidity ≤80%) Surface drying≤ 1 hour/dry ≤ 24 hours/hard drying≤7 days

(Note: The test conditions for salt water and salt spray resistance are: 1. Substrate: cold-rolled steel plate with degreasing and grinding; 2. Coating: spray epoxy zinc-rich primer twice + painted twice in epoxy micaceous iron; 3. Drying: Drying at room temperature for seven days. )

Fourth, the construction reference:

  • ◆Surface treatment: Safely remove impurities such as floating ash, floating rust, oil stain on the surface of the workpiece to be painted, and make the surface of the workpiece to be painted clean and dry;
  • ◆ Construction method: use airless or air spraying, spraying should use a large-caliber spray gun;
  • ◆ Mixing ratio: Component A: Component B = 4:1 (weight ratio), please stir the A and B components well before mixing;
  • ◆Dilution ratio: (component A + component B): water = 1:0.05~0.15, let stand for 5~10 minutes and then filter and spray with a 120 mesh filter cloth;
  • ◆ Construction viscosity: spraying: 30-40 seconds (coating -4 cups/23±2 °C);
  • ◆Recoating interval: not less than 12 hours (23±2°C);
  • ◆ Tank life: 1~2 hours (23±2°C, the validity period shortens with the increase of temperature); (Note: The life in the tank refers to the service life of A and B components after mixing).
  • ◆Drying method: self-drying at room temperature (15°C~40°C is appropriate), or 80°C~90°C drying (20~25 minutes);
  • ◆ Theoretical coating rate: 4 square meters/kg (based on 30 microns of dry film), the actual amount depends on the substrate structure and construction method.

5. Precautions:

  • ◆The quality of metal substrate treatment will directly affect the final effect and protective performance of the coating film;
  • ◆ The substrate must be coated as soon as possible after treatment, and the coating interval is not less than 12 hours and not more than 7 days (under the condition of 25 °C);
  • ◆ The construction temperature is required to be above 15 °C and below 40 °C, and above the dew point by more than 3 °C, and the relative humidity is ≥ 80%;
  • ◆ Outdoor construction can not be done on rainy days, if it has been constructed, it is necessary to cover it with a tarpaulin to protect the paint film that is not completely dry;
  • ◆ This product should be stored in a cool and ventilated place, the temperature is 5 °C ~ 45 °C, the validity period is one year, if the storage period is exceeded, it can still be used after passing the inspection.

6. Packing and Shipping:

  • ◆ Packing: 16kg/barrel for component A, 4kg/barrel for component B, specific packaging specifications can also be adjusted according to the actual situation;
  • ◆ Transportation: Transported as non-dangerous goods.