Using epoxy resin as the main raw material and has excellent chemical resistance and mechanical properties. Application field / Application areas: It is suitable for the coating of metal products with high requirements for corrosion resistance, electrical insulation and flexibility. It is generally not recommended to apply directly to the surface coating of various outdoor products.
Physical properties / Physical performance:1. Weight: 1.2-1.8 (depending on color and luster)
2. Storage: below 25℃, dry environment, good packaging for 6 months.
3. Packaging: 15 kg / box, carton packaging, lined with two layers of polyethylene inner bag.
Application specification / Application description:Surface treatment: treatment according to the substrate and the desired properties Spray spraying: static gun or friction gun
Membrane thickness: 60-70 um Curing conditions: Workpiece Temperature / Time: 140-200℃ x 15 minutes (depending on the specific product)
Coating performance
Characteristics | standard | result |
---|---|---|
Spraying area | 8-12 m2 / Kg membrane thickness 70 μ m (100% powder utilization) | |
Adhesion force | GB / T 9286 | Class 0 |
Impact | GB / T 1732 | 50cm |
Cupping test | GB / T 9753 | >=6MM |
Bend test | GB / T 6742 | <=3MM |
Pencil hardness | GB / 6739 | >=H |
Salt spray test | GB / T 1771 | 1000 h passed |
Damp heat resistant | GB / T 1740 | 1000 h passed |
Health & safety / Health and Safety: This powder coating is a non-toxic product, but dust inhalation should be avoided during use. It is recommended that operators wear appropriate dust masks and glasses. If possible, avoid long-term contact between skin and powder coating.
Safety & protection / Safety and Protection: All dust is irritating to the respiratory system, and steam should be avoided. Take measures to avoid skin contact. When necessary, wash the skin with water and soap. If the eyes make contact, immediately clean it with clean water and send it to the doctor in time. Gray layer and dust particles should be avoided at the surface and dead corners. Small organic particles will be ignited under static electricity and produce an explosion, all equipment needs to be ground to prevent static electricity.
Industrial pure polyester powder coating
Product description / Product Description:
Thermosetting powder coatings made using carboxypolyester resin Application field / Application areas: Usually known as environmental protection (non-toxic) weather resistance powder coating,
replace weather resistance powder coating for air conditioning machine, park appliances, lamp posts, outdoor furniture, lawn mower, agricultural machinery, etc., has the role of decoration and outdoor weather resistance.
Physical properties / Physical performance:
1. Weight: 1.2-1.8 (depending on color and luster)
2. Storage: below 35℃, dry environment, intact packaging condition for 12 months.
3. Packaging: 20 kg / box, carton packaging, lined with two layers of polyethylene inner bag.
Application specification / Application description:
Surface treatment: treatment according to the substrate and the desired properties
Spray spraying: static gun or friction gun
Membrane thickness: 60-70 um Curing conditions:
work piece temperature / time: 200℃ x 10 minutes
Coating performance / Film properties:
Characteristics | standard | result |
---|---|---|
Spraying area | 8-12 m2 / Kg membrane thickness 70 μ m (100% powder utilization) | |
Adhesion force | GB / T 9286 | 《=Class 1 |
Impact | GB / T 1732 | 50cm |
Cupping test | GB / T 9753 | >=6MM |
Pencil hardness | GB / 6739 | >=H |
Bend test | GB / T 6742 | <=3MM |
Salt spray test | GB / T 1771 | 500 h passed |
Damp heat resistant | GB / T 1740 | 1000 h passed |
indentation hardness | GB/T 9275 | ≥ 80 |
Resistance to heat and humidity | GB/T 1740 | 500 h passed |
Acid resistance | GB 9274 A method | 240H passed |
Water resistance | GB1733 B method | Passed |
Artificial accelerated aging | GB 1865 | 500h passed |
Health & safety / Health and Safety: This powder coating is a non-toxic product, but dust inhalation should be avoided during use. It is recommended that operators wear appropriate dust masks and glasses. If possible, avoid long-term contact between skin and powder coating.
Safety & protection / Safety and Protection: All dust is irritating to the respiratory system, and steam should be avoided. Take measures to avoid skin contact. When necessary, wash the skin with water and soap. If the eyes make contact, immediately clean it with clean water and send it to the doctor in time. Gray layer and dust particles should be avoided at the surface and dead corners. Small organic particles will be ignited under static electricity and produce an explosion. All equipment needs to be ground to prevent static electricity.
Powder coating for construction building
Product introduction / Product introduction:
Thermosetting powder coatings made with carboxylic resin and meet all typical requirements for coatings exposed to rainwater, snow fog, ultraviolet light in sunlight and sulfur dioxide atmosphere, etc.
Powder performance / Powder properties:
pigment AE powder coating is available in any color product, standard RAL color card color: for inventory, special color requirements, please contact us
Specific gravity 1.3-1.7 (depending on color and luster) distribution of size 100% <160 um, which can be adjusted to fit a specific application device flowability 120-160
lay in Below 35℃, dry environment, good packaging condition for 12 months pack 20 kg / box, carton packed, lined with polyethylene inner bag
Coating performance
Coating properties:
Characteristics | standard | result |
---|---|---|
Recommended membrane thickness | Locally <40um, mean membrane thickness of 60 – 120um | 60-80um |
lustre | 20-100% | 20-100% |
chromatic aberration | In accordance with the requirements of client | pass |
adhesive property | GB/T52374-2017 Dry adhesion, wet adhesion and boiling water adhesion reach level 0 | pass |
Boiling water resistance | pass | |
Impact force | GB/T537.4-2017, The punch diameter is 16±0.3mm, the hammer weighs 1000 ± 5g, and rushes out of the pit with a depth of 2.5±0.3mm, without shedding and cracking | pass |
cupping test | GB/T5237.4-2017,≥5mm | pass |
bend test | GB/T5237.4-2017≤3mm | pass |
indentation hardness | GB/T5237.4-2017, indentation <80 | pass |
salt spray test | GB/T5237.4-2017,1000h unilateral penetration corrosion width does not exceed 4mm | pass |
Resistance to heat and humidity | GB/T5237.4-2017, Comprehensive damage grade of 1000h coating shall reach Grade 1 | pass |
Haranic acid resistance | GB/T5237.4-2017 The membrane layer surface should have no bubbles or other obvious changes | pass |
solvent resistance | GB/T5237.4-2017, should be level 3 or level 4 | pass |
mortar Resistant | GB/T5237.4-2017, No bubbles or other obvious changes in the coating | pass |
Artificial accelerated aging | GB/T5237.4-2017,1000h xenon lamp test, 50% light retention rate, and color difference according to YS / T 680-2016 | pass |
Natural weather resistance | GB/T5237.4-2017,1 year exposure test, light protection rate of 50%, color difference according to YS / T 680-2016 | pass |
Construction guide / Construction guide: Preprocessing: For Architecture series products to achieve their best performance, the pretreatment must be performed according to the construction guidelines for Architecture series products.
Aluminum, steel and galvanized steel: careful chemical reactions to achieve the required level of corrosion protection.
Steel and hot-dip galvanized steel, you can use our anticorrosive protection primer (please consult us).
Curing guide: artifact Temperature / time: 200℃ x 10 minutes Safety & protection / Safety and Protection: All dust is irritating to the respiratory system, and steam should be avoided.
Take measures to avoid skin contact. When necessary, wash the skin with water and soap.
If the eyes make contact with it, immediately clean it with clean water and send it to the doctor in time.
Gray layer and dust particles should be avoided at the surface and dead corners.
Small organic particles will be ignited under static electricity and produce an explosion. All equipment needs to be ground to prevent static electricity